Performance of the rapid high-throughput automated electrochemiluminescence immunoassay targeting total antibodies to the SARS-CoV-2 spike protein receptor binding domain in comparison to the neutralization assay.

Título

Performance of the rapid high-throughput automated electrochemiluminescence immunoassay targeting total antibodies to the SARS-CoV-2 spike protein receptor binding domain in comparison to the neutralization assay.

Autor

Mario Poljak, Katarina Resman Rus, Miša Korva, Nataša Knap, Tatjana Avšič Županc

Descripción

Neutralization tests (NT) are the gold standard for detecting and quantifying anti-SARS-CoV-2 neutralizing antibodies (NAb), but their complexity restricts them to research settings or reference laboratories. Antibodies against S protein receptor binding domain (RBD) have been shown to confer a neutralizing activity against SARS-CoV-2. Assays quantitatively measuring anti-S1-RBD-SARS-CoV-2 antibodies could be of great value for NAb screening of potential donors for convalescent-phase plasma therapy, assessing natural or vaccine-induced immunity, stratifying individuals for vaccine receipt, and documenting vaccine response. Elecsys Anti-SARS-CoV-2 S (Elecsys-S), a high-throughput automated electrochemiluminescence double-antigen sandwich immunoassay for quantitative measurement of pan-anti-S1-RBD-SARS-CoV-2 antibodies, was evaluated against NT on 357 patients with PCR-confirmed SARS-CoV-2 infection. NT was performed in a BSL-3 laboratory using a Slovenian SARS-CoV-2 isolate; the NT titer ≥1:20 was considered positive. Elecsys-S detected pan-anti-S1-RBD-SARS-CoV-2 antibodies in 352/357 (98.6 %) samples. NAb were identified by NT in 257/357 (72 %) samples. The Elecsys-S/NT agreement was moderate (Cohen's kappa 0.56). High NT titer antibodies (≥1:160) were detected in 106/357 (30 %) samples. Elecsys-S's pan-anti-S1-RBD-SARS-CoV-2 antibody concentrations correlated with individual NT titer categories (the lowest concentrations were identified in NT-negative samples and the highest in samples with NT titer 1:1,280), and the Elecsys-S cutoff value for reasonable prediction of NAb generated after natural infection was established (133 BAU/mL). Although NT should remain the gold standard for assessing candidates for convalescent-phase plasma donors, selected commercial anti-SARS-CoV-2 assays with optimized cutoff, like Elecsys-S, could be used for rapid, automated, and large-scale screening of individuals with clinically relevant NAb levels as suitable donors.

Fecha

2021

Materia

antibody, neutralization, SARS-CoV-2, immuno-assay, Electrochemiluminescence

Identificador

10.1016/j.jcv.2021.104820

Fuente

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology

Archivos

https://socictopen.socict.org/files/to_import/pdfs/bb3ddce5d603ac46ce24a8602cdbe9d0.pdf

Colección

Citación

Mario Poljak, Katarina Resman Rus, Miša Korva, Nataša Knap, Tatjana Avšič Županc, “Performance of the rapid high-throughput automated electrochemiluminescence immunoassay targeting total antibodies to the SARS-CoV-2 spike protein receptor binding domain in comparison to the neutralization assay.,” SOCICT Open, consulta 19 de abril de 2026, https://www.socictopen.socict.org/items/show/5869.

Formatos de Salida

Position: 19222 (15 views)